1. Barometric pressure measurement performance

Specifications Value
Observation range 500 … 1100 hPa

Accuracy (for sensor element) at 600 … 1100 hPa

±0.5 hPa at 0 … +30 °C (+32 … +86 °F)
±1 hPa at −52 … +60 °C
(−60 … +140 °F)
Output resolution 0.1 hPa / 10 Pa / 0.001 bar /
0.1 mmHg / 0.01 inHg

2. Air temperature measurement performance

Specifications Value
Observation range 52 … +60 °C (60 … +140 °F)
Accuracy (for sensor element) at +20 °C (+68 °F)  ±0,3 °C (±0,54 °F)
Output resolution 0.1 °C (0.1 °F)

3. Relative humidity measurement performance

Specifications Value
bservation range 0 … 100 %RH
Accuracy (for sensor element)

±3 %RH at 0 … 90 %RH

±5%RH at 90…100%RH

Output resolution 0.1% RH

4. Wind measurement performance

Specifications Value
Wind speed  
Observation range 0 … 60 m/s (134 mph)
Reporting range  0 … 75 m/s (168 mph)
Response time 0.25s
Available variables Average, maximum, and minimum
Accuracy ±3 % at 10 m/s (22 mph)
Output resolution 0,1 m/s (km/h, mph, knots)
Wind direction  
Azimuth 0 … 360°
Response time 0.25 giây
Available variables Average, maximum, and minimum
Accuracy ±3,0° at10 m/s (22 mph)
Output resolution
Averaging time 1 … 3600s, sample rate 1, 2, or 4 Hz
(configurable)

5. Operating environment

Specifications Value
Operating environment  Outdoor use
Operating temperature 52 … +60 °C (60 … +140 °F)
Storage temperature 60 … +70 °C (76 … +158 °F)
Operating humidity 0 … 100 %RH
Operating pressure 500 … 1100 hPa
Wind 1)  0 … 60 m/s (0 … 134 mph)
IP rating

Without mounting kit: IP65
With mounting kit: IP66

1) Due to the measurement frequency used in the sonic transducers, RF interference in the
200 … 400 kHz range can disturb wind measurement.  

6. Precipitation measurement performance

Specifications Value
Collecting area 60 cm2 (9.3 in2 )
Rainfall1)  
Output resolution  0.01 mm (0.001 inch)
Field accuracy for daily accumulation  Better than 5 %, weather-dependent
Duration Counting each 10‑second increment whenever droplet detected
Duration output resolution 10s
Intensity Running 1‑minute average, 10 s steps
Intensity observation range

0 … 200 mm/h (0 … 7,87 in/h)

(broader with reduced accuracy)

Intensity output resolution 0.1 mm/h (0.01 inch/h)
Hail 2)  
Output resolution 0.1 hits/cm2 (1 hits/in2 ), 1 hit
Intensity output resolution 0.1 hits/cm2h (1 hits/in2h), 1 hits/h

1) Cumulative accumulation after the latest automatic or manual reset.

2) Cumulative number of hits against collecting surface.

7. Inputs and outputs

Specifications Value
Operating voltage 6 … 24 V DC (10 … +30 %)
Average power consumption

Minimum: 0.1 mA at 12 V DC (SDI‑12
standby)
Typical: 3.5 mA at 12 V DC (typical
measuring intervals)
Maximum: 15 mA at 6 V DC (constant
measurement of all parameters)

Heating voltage 

DC, AC, or full-wave rectified AC

12 … 24 V DC (10 … +30 %)

12 … 17 V ACrms (10 … +30 %)

Typical heating current  12V DC: 800mA, 24V DC: 400mA
Digital outputs SDI-12, RS-232, RS-485, RS-422
Communication protocols

SDI-12 v1.3, Modbus RTU,

ASCII automatic and polled,

NMEA 0183 v3.0 with query option

8. Analog input options

Specifications Value
Solar radiation 0 … 25 mV
Voltage input 0 … 2,5 V, 0 … 5 V, 0 … 10 V 
Tipping bucket rain gauge 0 … 100 Hz
Temperature (Pt1000) 800 … 1330 Ω

9. Analog mA output options

Specifications Value
Wind speed 0 … 20 mA or 4 … 20 mA
Wind direction 0 … 20 mA or 4 … 20 mA

10. Compliance

Category Standard
EU directives and regulations EMC, RoHS
EMC compatibility

EN 61326-1, industrial environment

CISPR 32 / EN 55032, Class B

Environmental

IEC 60068‑2‑1, 2, 6, 14, 30, 31, 78

IEC 60529, VDA 621‑415

Maritime

IEC 60945 (Exposed)
DNV GL Type Examination Certificate
No. TAA00000VF

Compliance marks CE, RCM, RoHS, RoHS Trung Quốc, UKCA